A794 Owner’s Guide Chapter 6: Programming Information
December 1999 113
Real Time Status Transmission (continued)
2 = Transmit RS-232C Busy Status
Bit Status Hex Decimal Function
0 Off 00 0 Fixed to Off.
1 On 02 2 Fixed to On.
2Off
On
00
04
0
4
Cover closed.
Cover open.
3Off
On
00
08
0
8
Paper Feed Button is not pressed.
Paper Feed Button is pressed.
4 On 10 16 Fixed to On.
5Off
On
00
20
0
32
Printing not stopped due to paper condition.
Printing stopped due to paper condition.
6Off
On
00
40
0
64
No error condition.
Error condition exists in the printer.
7 Off 00 0 Fixed to Off.
3 = Transmit Error Status
Bit Status Hex Decimal Function
0 Off 00 0 Fixed to Off.
1 On 02 2 Fixed to On.
2 Off 00 0 Fixed to Off.
3Off
On
00
08
0
8
No knife error.
Knife error occurred.
4 On 10 16 Fixed to On.
5Off
On
00
20
0
32
No unrecoverable error.
Unrecoverable error occurred.
6Off
On
00
40
0
64
Thermal printhead temp. and power supply
voltage are in range.
Thermal print head temp. or power supply
voltage are out of range.
7 Off 00 0 Fixed to Off