7193 Owner’s Guide Chapter 5: Communication
August 1998 39
Parallel Interface
Parallel Protocol
The 7193 uses a standard PC-compatible parallel interface. The illustration shows the
timing diagram for the interface protocol.
B U S Y
ACK
D A T A
STRO BE
0.5 µs (Min.)
1.0 µs (Min.)
0.5 µs (Min.)
0.08 µs (Min.)
S ee N o . 1
A pp. 0.06 µs
1.
ACK/ will not go high until STROBE/ goes high.
2.
When the printer is not ready to receive more data, ACK/ will be sent, but BUSY will
remain high.
3.
When the power is turned on or the printer is reset, an ACK/ will be sent during
initialization.
4.
Typical time from STROBE/ to ACK/ is approximately 44 µ seconds.